Tender Details
Category:
Infrastructure & Construction
Important Dates
Publish Date:
28 September 2026
Submission Date:
08 October 2026
Opening Date:
30 November -0001
Description
Biliry Stentbiliry Stent,Srphc82336065-Biliary Stone Extraction Baloon Small Size(9-12Mm).Catheter Sh Ould Be Easily Back Loaded Over A Guidewire With Enough Stiffness For Improved "Pushabili Ty". It Should Enable Front Or Back Loading Of Guidewire And Offers Injection-Above Or Inje Ction-Below Options To Support Physician Preference And Facilitate Procedural Needs With Excellent Injection Flow Rate.Tapered Tip 7 -6 F .Balloon Diameter 9 To 12 Mm.Length 200 To 230 Cm. ] , Srphc82336044-Biliary Radio Frequency Ablation Electrode:A) Should Have Mult Iple Bipolar Electrode Enables Linear Ablation Zone.B) Should Have Electrode Length 33Mm /18Mm/22Mm & 11Mm. C) Should Have Catheter Diameter 7Fr Compatible With 0.035" Guide Wire . ] , Srphc82336055-Biliary Stone Extraction Balloon Large Size 15-18 Mm. Catheter Should Be Easily Back Loaded Over A Guidewire With Enough Stiffness For Improved "Pusha Bility".It Should Enable Front Or Back Loading Of Guidewire And Offers Injection-Above Or I Njection-Below Options To Support Physician Preference And Facilitate Procedural Needs With Excellent Injection Flow Rate.Tapered Tip 7 - 6 F.Balloon Diameter 15 To 18 Mm.Length 2 00 To 230 Cm. ] , Srphc82336040-Biliary Metal Stent-It Is A Fully Covered Removable Metal Stent Should Be Made Of Alloy Material To Allow Greater Flexibility And Use In Tortuous Anatom Y. Stent Lengths 4 Or 6 Or 8Cm With Retrieval String. Removability Indication Up To 12 Mont Hs After Placement For The Fully Covered Stent And Should Be Reconstrainable Even After 80% Of Deployment. ] , Srphc82336035-Biliary Metal Stent-1. It Is A Uncovered Metal Stent Should Be M Ade Of Alloy Material. 2. Should Have Various Lengths 6 Or 8 Or 10Cm.. 3. Should Have 6Fr D Elivery Catheter..4. Should Have Tapered Tip. ] , Srphc82336030-Biliary Metal Stent- 1. It Is A Uncovered Metal Stent Should Be M Ade Of Alloy Material. 2. Should Have Various Lengths 6 Or 8 Or 10Cm. 3.Should Have 7Fr To 8Fr Delivery Catheter. 4.Should Have Tapered Tip. ] , Srphc82336050-Biliary Stent Straight. Should Be Made Up Of Polyethylene With Teflon Coated . The Stent Should Be Available In Sizes From 5 Fr To 11.5 Fr And Length 3 To 21 Cm. Should Have Coloured Markings At The Distal End. ] , Srphc82336070-Cervical Esophageal Stent: A) Proximal Release Fully Silicone C Overed Esophageal Stent. B) Short Proximal Head Design. C) Visible Green Suture On The Pr Oximal End For Removal. D) 4Ro Marker At Both Ends And 2 In The Middle. E) Stent Diameter 1 8Mm And 20Mm. F) Stent Length 6,8,10,12,14 And 15Cm. G) Delivery Profile 20Fr. ] , Srphc82336060-Biliary Stone Extraction Balloon Medium Size 12-15 Mm.Catheter Should Be Easily Back Loaded Over A Guidewire With Enough Stiffness For Improved "Pusha Bility".It Should Enable Front Or Back Loading Of Guidewire And Offers Injection-Above Or I Njection-Below Options To Support Physician Preference And Facilitate Procedural Needs With Excellent Injection Flow Rate.Tapered Tip 7 To 6 F.Balloon Diameter 12 To 15 Mmlength 200 To 230 Cm. ] , Srphc82336025-Biliary Metal Stent Consists Of 30Fr(10Mm)Lumen Stent And 8Fr C Atheter. It Is A Partially Covered Stent With Lengths 4Cm Or 6Cm And Diameter 10Mm. ]