Importance of Cold-Formed Steel in Seismic-Resistant Design of Structures

Cold Formed Steel is a product made by rolling steel or pressing steel in to semi-finished or finished goods at relatively low temperatures. Manufacturing of Cold Formed Steel (CFS) occurs at room temperature. In present scenario the use of CFS system is significantly increasing in countries where traditional structural solutions have always dominated the construction sector. This is mainly due to the developing and increasing technical, structural and economic competitiveness of such systems. The advantages with CFS are lightness of systems, high quality of end products, flexibility due to wide variety of shapes and section dimensions, short execution time due to dry constructions and minimization of environmental impacts due to the possibility to reuse the elements at the end of the life cycle. This paper presents the importance of CFS in various structural elements to mitigate the damage cost to these elements during earthquakes. These elements are investigated for seismic resistance in multi storey moment frames, factors like premature local buckling and low out of plain stiffeners known as the main structural deficiencies of CFS with thin walled elements hence in structures with CFS as the main load bearing components there is less energy dissipation due the above mention deficiencies. Therefore in order to improve the energy dissipation of CFS, an innovative CFS beam with curved flange was developed. The main aim of beam was to produce plastic moment due to large width thickness ratios of thin walled elements of CFS section; development of plastic moment was avoided. To overcome these limitations, the CFS elements were introduced with flange bends in C section leading to a curved flange section. Also modification like flange lips, introducing intermediate flange stiffeners and increasing the number of flange bends results in increase in moment resistance, ductility capacity and initial stiffness. Steel sheeted CFS using gypsum board claddings with different configuration on shear walls and partition walls on either or both sides resulted in increased of lateral stiffeners; shear strength and energy dissipation capacity. Use of MLC (Modular Light weight Cold Form beams) are designed to prevent early buckling phenomena that could affect the structural behaviour when thin sheets are used also provide high resistance to torsional flexural buckling.

Sanket Desai, Akshaykumar Sanaki, M.Tech Structural Engineering Student, N Munirudrappa, Proffesor, Dept. Of Civil Engineering, Dayananda Sagar College of Engineering, K. S. Layout, Bangalore, Karnataka, India.

sanket

Introduction

The use of Cold-Formed Steel system is significantly increasing in the countries where traditional structural solutions have always dominated the construction sector. This is due to recognized technical, structural and economic competitiveness of such systems. The CFS members obtained by cold rolling are produced by pressing or bending steel sheaths with thickness ranging between 0.4-0.7mm. These members provide several advantages such as lightness of structural systems, high quality of end products, flexibility due to wide variety of shapes and sectional dimensions, short execution period and minimization of environmental impacts.

In steel structures located in seismic area, factors like premature local buckling and low out of plain stiffness are regarded as main structural deficiencies. The use of Cold-Formed Steel structural systems in such area improves the energy dissipation property of the structure which accounts for the seismic resistance. These sections have a high potential for premature failures because of their thin walled nature. To reduce the chances of failures ample ductility should be imparted to the sections.

sanket

Advantages of Cold Rolled Steel
  • Some of the advantages of cold rolled sections as compared to the hot rolled counterparts are as follows:
  • Cross-sectional shapes are formed to close tolerances and these can be consistently repeated for as long as required
  • Cold rolling can be employed to produce any desired shape to any desired length
  • Pre-galvanized or pre-coated metals can be formed so that high resistance to corrosion, besides an attractive surface finish can be achieved.
  • All conventional connection methods i.e., riveting, bolting, welding, etc can be employed.
  • High strength to weight ratio can be achieved in cold rolled sections.
  • They are usually light in weight, easy to transport and erect.
Case Studies
Experimental work on CFS elements for earthquake resilient moment frame buildings.

Experimental investigation on the use of thin walled cold-formed sections as energy dissipative elements for earthquake resistant moment frame for multi-storey buildings were carried out. In multi-story moment frames use of CFS often led to premature local buckling and low out of plane stiffness. To overcome these deficiencies the following experimental investigation was carried out. The tests were performed on 6 bolted beams to column connections with two different beam thicknesses 3mm and 4mm respectively. The test involved step-by-step development curved flange sections and beams with different types out of plane stiffeners in the connection region; the three configurations of the stiffener connections being: without stiffener, minimum stiffener and optimum stiffener. The test specimens were subjected to cyclic loading through hinge connections at the beam end. From the results obtained through the experiment it as concluded that:

  1. The premature buckling due to discontinuity in the flange connection can be delayed by using combination of vertical or horizontal out of plane stiffeners.
  2. Ductility factor was increased by 75%, moment strength by 35% and energy dissipation by 240%.

flanged beams
Figure 1: a) Different flange shape layouts; b) 3-D simulated view of curved flanged beams

Damage Control systems

In order to control rocking behaviour of cold formed steel in multi-storey shear walls an innovative damage control system was proposed. The system involved hold-down equipped with a fuse function and was placed on the foundation of multi-storey shear walls. This HDF (hold-down fuse) reduces the damage to both structural and non-structural members in the cold-formed steel buildings.

To understand the basic behaviour of proposed controlling racking systems in an earthquake, shake table tests were performed using one storey, one span, real size specimens. The specimen consisted of steel sheet shear wall with a height and width of 3000 and 6000mm respectively and steel bracings with height and width of 3000 and 1500mm respectively.

Two steel shear walls were set parallel to the shake direction. Figure shows the controlled-rocking system with multi-storey shear walls for cold-formed fuse frames. In this system, a fuse made of a steel plate which was placed between the racking frames and the foundation. It was connected to a channel of the upper frame and an anchor bolt supported by the foundation. In conventional cold-formed steel structures a frame is rigidly connected to the foundation by steel hold-downs. Therefore the building dissipates the earthquake energy mainly through plastic deformation of shear walls or bracing members in upper frames. Whereas, the newly proposed HDF’s dissipate most of the seismic energy and as a result member and walls within the frame sustain less damage.

Experimental set up
Figure 2: Experimental set-up.

Shake table tests of a cold-formed steel shear panel

Several investigators have tested CFS shear walls for static cyclic loadings and the results were evaluated. But, there is very limited literature available for the performance of CFS shear walls under dynamic loadings. To account for this, a shake table test of a full scale two storey single bay structure was conducted. They were separated by 3.9m centre to centre in the out of plane direction.

The shear panel was 2.8m wide and the storey height was 3m. Both the storeys were identical but the bottom storey was subjected to greater loads. The exterior columns were built-up by channel sections and were welded to the steel anchors and bolted to the slab.

steel fuse
Figure 3: Hold-down steel fuse

The slab was a heavy reinforced one, 200mm thick and 4.40mm2 in area weighing 93kN. This slab acted as a rigid diaphragm. The specimen design was done considering the location of Seattle, Washington using the data guidelines from TI 809-07 (III). The seismic base shear for the shake table was estimated to be 96.1kN per frame. However the frames were designed for a base shear of 96.4kN each. Shake table specimen was instrumented with accelerometers, displacement gauges and strain gauges.

Through the test results it was seen that the thin steel straps used a cross bracing in CFS buildings are very tough and ductile. After the local buckling, the CFS built-up exterior columns performed well. The columns contribution to the shear capacity of structure was minimum but dependable throughout earth-quake simulation. When the bracings failed to provide strength and stiffness to the earth-quake responses, the columns provided energy dissipation.

The CFS structure provided to be a very affective and dependable structural system for seismic loads and provide the bracing member is prevented from fracture.

flanged-beams
Figure 4: a) Different flange shape layouts; b) 3-D simulated view of curved flanged beams

Seismic behaviour of sheathed CFS shear walls cladded by gypsum and fiber cement boards.

Experiments are carried out to investigate the seismic response of steel sheathed CFS shear walls using gypsum and fibre cement board claddings. The experiment was carried out on six such specimens of various configurations and was tested under cyclic loading. With the introduction of claddings, it imposed additional forces on the members in the load path towards the foundation which resulted in the increases of shear strength of walls. Also use of single and double sided steel sheathing on CFS shear walls increased their shear strength and energy dissipation capacity. It was concluded that the shear strength and secant stiffness of CFS steel sheathed walls can be increased by 30% to 32% for single sided and 61% to 80% for double sided claddidng.

Conclusions

Experimental Set up
Figure 5: Experimental Set-up
Use of CFS products are important and effective in the constructions carried out especially in seismic areas; lightweight structural systems, high quality end products, flexibility, short execution period, minimum impacts on the environment are some of the important properties of CFS systems which make them suitable for seismic areas.

CFS systems are under research and some of the research works discussed above yield the following conclusions:
  • With the use of curved flange beams in earthquake resistant moment frame multi-story buildings resulted in the increase of ductility (upto75%) and moment capacity (upto35%) and also hysteretic energy dissipation capacity (upto240%).
  • By providing single and double sided gypsum and fiber cement cladding CFS steel sheathed walls, the shear strength and energy dissipation capacity can be increased by 31% and 32% for single sided cladding and up to 80% and 67% for double sided cladding
  • With the use of vertical/horizontal out of plane stiffeners the premature buckling due to discontinuity in the flange is delayed.
Table 1. Shear wall test specimens.
Specimen Front side sheathing/cladding Back side cladding
S Steel sheet (S)
S-G Steel sheet (S) Gypsum board (G)
S-C Steel sheet (S) Fiber cement board (C)
GS-G CS-G CS-C Gypsum board Steel sheet (GS)
Fiber cement board Steel sheet (CS)
Fiber cement board Steel sheet (CS)
Gypsum board (G)
Gypsum board (G)
Fiber cement board (C)

Plan cross-sections

References

  1. R. Retamales, R. Davies, G. Mosqueda, and A. Filiatrault. ASCE (2013). “Experimental Seismic Fragility of Cold-Formed Steel Framed Gypsum Partition Walls”.
  2. Bagheri, S. Mihail, et.al.“Novel Cold-formed Steel Elements for Seismic Applications”. Twenty-First International Specialty Conference on Cold-Formed Steel Structures St. Louis, Missouri, USA, October 24 & 25, 2012.
  3. T. N. Dao, and W. John, V.D. Lindt. “Seismic Performance of an Innovative Light-Frame Cold-Formed Steel Frame for Midrise Construction”. ASCE (2013).
  4. B.W.Schafer, Johns Hopkins University Bonnie Manley, American Iron and Steel Institute. “Advancing Cold-Formed Steel Earthquake Engineering”. 10th U.S national conference on earthquake engineering. (2014)
  5. B.W. Schafer “Cold-formed steel structures around the world” (2011).
  6. B.W. Schafer “Cold-formed steel structures: special issue”. Journal of Structural Engineering ASCE April 2006.
  7. H. Moghimi, and R. G. Driver. “Economical Steel Plate Shear Walls for Low-Seismic Regions”. ASCE (2013)
  8. M .Lecce and K. J. Rasmussen. “Distortional buckling of cold – formed stainless steel sections: Experimental investigation”. ASCE (2012).
  9. Y.B. Kwin, H.S. Chung, and G.D. Kim. “Experiments on cold – formed steel connections and portal frames. ASCE (2006).
  10. S, Mohebbi, S.R. Mirghaderi, et.al. “Experiments on Seismic Behaviour of Steel Sheathed Cold – Formed Steel Shear Walls Cladded by Gypsum and Fibre Cement Boards”. Elsevier journal (2016).
  11. N. Delattle “Failure of Cold -Formed Steel Beams During Concrete Placement.” ASCE (2005).
  12. G.D. Corte, L. Fiorino, and R. Landolfo. “Seismic Behaviour of Sheathed Cold – Formed Structures: Numerical Study”. ASCE (2006).
  13. A.Sato and C.M.Uang. “Seismic Performance Factors for Cold-Formed Steel Special Bolted Moment Frames.” ASCE (2010).
  14. R. Parnell, B.W. Davis and L. Xu. “Vibration Performance of Lightweight Cold-Formed Steel Floors”. ASCE (2010).

NBM&CW August 2018

Click Here
To Know More / Contact The Manufacturer
Please provide your details we will contact you as soon as possible
Please let us know your name.
Invalid Input
Please let us know your Designation.
Invalid Input
Please let us know your City.
Please let us know your State.
Please let us know your Country.
Please let us know your Contact Number.
Please let us know your email address.
Please brief your query.

Fire Resistance of Steel Structures

Structural steel frames are widely used in virtually all types of buildings and industrial installations. Fire-resistant design of structural steel framing is often required, depending on the fire risks Read More ...

Utilization of Steel Slag in Construction Materials

Paver blocks and steel slag binder bricks
Steel slag, a by-product of steel making, is produced during the separation of the molten steel from impurities in steel-making furnaces. Slag whether granulated or crystalline is an important Read More ...

Parametric Study for the Economical Depth of Long Span Arch Type Truss

Arch type space truss
A space frame or space structure is a truss-like, lightweight rigid structure constructed from interlocking struts in a geometric pattern. Space frames can be used to span large areas with few interior supports Read More ...

A Study on Properties of Polypropylene Fibre-Mesh

Fibre Mesh
Concrete is widely used constructional material with its high compressive strength. But it has some flaws like shrinkage and cracking, low tensile and flexural strength, poor toughness Read More ...

Pre-Engineered Construction in India a way forward!

Pre Engineered Construction
The Indian Construction Industry has witnessed a growth trajectory quite comparable to the development of the overall economic infrastructure of the country. The Indian Pre-Engineered Steel Buildings Read More ...

The Growing Demand of Aluminium Extrusions

Aluminium Extrusions
Aluminium - the third most abundant element in the earth's crust finds its implementation in many sectors due to its environment and user -friendly nature - in Building and Construction (B&C), power sector, automotive Read More ...

Steel in vogue for highrise buildings

high rise structure for office
There is no doubt looking at the way the population density particularly in metro cities, horizontal construction has been put on restriction, and comfortably spread out real estate is hard to find. Lack of space Read More ...

Interarch Infrastructure

Interarch office space
Heavy Steel Structure and large infrastructure projects hold nearly 20% share of the infrastructure work that is taking place in our country currently. Indian engineering industry has witnessed an extraordinary Read More ...

Pre-engineered Building PEB System hit Indian construction market

Pre-engineered Building
India has the second fastest growing economy in the world and a lot of it, is attributed to its construction industry which figures just next to agriculture in its economic contribution to the nation. In its steadfast Read More ...

Pre-engineered for Success: Tracking growth of PEB Steel buildings in India

PEB Steel buildings
As Infrastructure construction across the country is combining speed, economy, safety, strength and aesthetics at awe inspiring levels, steel structures, until now a primary foundation element, have risen Read More ...

Performance Assessment of Coated Steel

Coated Steel
There are different assessment options available for performance evaluation of coated steel. This article will give some inside to readers on important performance evaluation options related to physical testing Read More ...

Contemporary Industrial Building Methods

Contemporary Industrial Building
India is on its drive for a massive infrastructure upgrade and the construction techniques in the country have seen a major elevation over the past few years with the adoption of global practices Read More ...

Design Flexibility in Construction with Steel

Construction With Steel
Steel has become a universal building product due to its strength, versatility, durability and economic value. The use of coated steel for structures, roofing & wall cladding is growing rapidly because it offers Read More ...

TCS Campus Siruseri - Chennai

TCS Campus Siruseri
Tata Consultancy Services (TCS) India is building a new $200 million IT Park in Siruseri, Chennai. Designed by Uruguayan architectural firm Carlos Ott Architects in association with Carlos Ponce de León Architects, Read More ...

Design of Long Span Steel Structures and Hangars

Span Steel Structures
The majority of industrial buildings are made out of steel for obvious reasons of high strength/weight ratio. A study, on the Efficient Design of Large span hangars/structures, ensuring lighter foundations Read More ...

Pre–engineered Building Systems A Promising Future

Pre–engineered Building Systems
Technological improvement over the year has contributed immensely to the enhancement of quality of life through various new products and services. One such revolution was the pre–engineered buildings Read More ...
NBM&CW

New Building Material & Construction World

New Building Material & Construction World
MGS Architecture

Modern Green Structures & Architecture

Modern Green Structures & Architecture
L&ST

Lifting & Specialized Transport

Lifting & Specialized Transport
II&TW

Indian Infrastructure & Tenders Week

Indian Infrastructure & Tenders Week